Scales
3 min
pair a feed scale to using your mobile device's bluetooth connection make sure that bluetooth is enabled on your mobile device, and then connect it on the account settings docid\ fvv544s3nm30ypvgfjdza screen in the app note that some scales may require configuration before you connect it to the important if you connect to equipment containing an overnight load, an overnight load notification with a red alert icon is displayed you'll need to use other equipment until the overnight load is completed see mix overnight loads docid\ acj67fjs4bzvcoypkeur2 to learn more supported scales indicator indicator (ez2810 and ez3410) you can check the feedcomp system requirements https //vas com/feedcomp minimum system requirements/ page on the website to confirm whether your device is supported and compatible with expand the sections below to learn more connect a scale tap your user icon at the top right of the screen settings select the to connect tap connect to scale and select the scale to connect after a scale is connected to your mobile device, the bluetooth icon displays at the top left of each screen in the configure a topcon digi star scale before you connect a to the , you must confirm that the scale settings match the settings docid\ syetsrvivw35b9cvaimxb listed below the connection may not work if the settings do not match note if you use trioliet shifttronic products with your scale, contact support at fwsupport\@vas com mailto\ fwsupport\@vas com or to ensure that you apply the correct settings for your configuration review or configure scale settings follow the steps below to review or configure the settings on your scale to make sure they match the required settings docid\ syetsrvivw35b9cvaimxb note if you have an indicator with a number pad, you can manually enter each direct access number (d a n ) for each parameter in required settings docid\ syetsrvivw35b9cvaimxb , then review or configure each setting on your , press select repeatedly until the menu is displayed press and hold function until you see the menu choices repeatedly press select to select menu 1, 2, 3, 4, or 5 press enter to view the first setting name pay close attention the setting name only displays once check whether the setting is configured to the value listed in required settings docid\ syetsrvivw35b9cvaimxb if the setting is not configured correctly, press net/gross or select to scroll through the options and press enter to select the correct value the screen automatically displays the next setting if the setting is configured correctly, press enter to review the next setting repeat the steps to review or configure each setting in each menu required settings direct access number setting name display name value 1003 scale id setup scalid tmr 01 1008 display unit select the display unit pounds (lbs) or kilograms (kg) lbs kgs lbs or kgs 1411 remote input 2 rimpr2 print 2001 remote remote on 2101 scoreboard mode scorem 12 2103 front panel zerout zerofp off 2104 n/a scrm 2 0 2111 operation status opstat 0 2301 tare auto print tareap on 2302 one line print il pt on 2304 print format prtfmt prtac1 2401 remote display radisp ez3mux 2402 remote terminal rmterm off 2403 n/a autodrt on 2411 bar graph bargaph off 2412 weight graph wtgrah on 2417 n/a nondsp off 3001 display count only set this value if you need to update the display count increments shown on the scale this value is also used to round off the preset value by the scale you cannot change this value in the app count select the preferred value 4001 pre alarm method p mthd weight 4002 pre alarm if you set this value, a warning is activated when the indicator approaches this value for example, if you set the value to 50 (lbs/kgs), a warning alerts you when 50 (lbs/kgs) are set to be loaded or unloaded p alm select the preferred value 4006 preset delay prtdly 1 4009 n/a prtclp on 4012 this setting hides the preset message display after 10% of the target weight has been loaded or unloaded weitog off 4201 tolerance method t mthd weight 4202 tolerance toler 0 5001 remote display rmdisp com3 5002 radio port radprt com3 5003 external radio port exrprt com2 5005 printer port prtport com3 5006 scoreboard port scport com3 5007 opstat port opstat com1 5009 ddl port ddlprt com2 5011 20ma mirror port 2omamr com1 5015 n/a sl2art com2 5016 n/a dlport com3 5018 n/a am2drt com3 connect the indicator to the feedcomp app after you confirm that the scale settings match the required settings, connect the indicator to your mobile device via bluetooth open your mobile device's bluetooth settings connect the indicator after it is connected, shut down the app completely and make sure it is cleared from your list of background apps follow the instructions in connect a scale docid\ syetsrvivw35b9cvaimxb to connect the scale to the calibrate the scale if you have a completely new , calibrate the indicator to ensure that all the measurements are accurate watch the video to learn how troubleshoot a scale connection if the connection fails when you attempt to connect a scale docid\ syetsrvivw35b9cvaimxb , check the following, depending on your scale model topcon digi star scale verify that no other devices are currently connected to the scale only one device can be connected to a at a time check the id and make sure it starts with "tmr " expandableheading expand for steps to check or change the scale id on the keypad, enter 1003 and press select the current id displays if the id does not start with "tmr ", use the keypad to change it press enter to save the id \ verify that bluetooth is enabled on the expandableheading expand for steps to enable bluetooth on the keypad, enter 90022 and press select if the display shows an error message, press the zero button four times and then on the keypad shows the current bluetooth setting as on or off if bluetooth is off, press the function button to select on and enter to save the setting \ if crashed on your device the last time it was connected to the scale, the connection may still be active turn the scale off and back on then reconnect the scale from ensure that the settings match the settings listed in configure a topcon digi star scale docid\ syetsrvivw35b9cvaimxb if you use a and the will not complete a drop or automatically advance to the next , make sure that the mixer's drop tolerance is set to a minimum value of 1 if you use 0 for the drop tolerance value, the may not complete drops correctly to update your mixer's drop tolerance, tap at the bottom of the screen, tap , and select the mixer to make your changes scale tec point scale if crashed on your device the last time it was connected to the scale, the connection may still be active turn the scale off and back on then reconnect the scale from reference the scale tec support center https //support scale tec com/portal/en/kb/point if you are having other issues tip you're currently viewing for in the mobile app click here to see online help for settings in feedcomp on pulse docid\ n32oxpiq3cgb04icve bp < return to feedcomp app home page docid\ phailrt1hjrpzhxilgb k